inconsistency between two sums of the total continuum
A summer school participant pointed out that two sums which are advertised as being the same quantity, are slightly different. At r9474 with gcc/mac the smoke test results in these two entries in the main block of emission line
Inci 0 2.562
TALL 10000.0A 2.559
They are the same thing - the sum over the full radiation field. They differ by 0.003 dex, ~0.7%. Due to differences in the quadrature used for Inci vs the simple sum used for TALL?
From "save line labels"
6 Inci 0 total luminosity in incident continuum
332 TALL 10000.0A continuum bands defined in continuum_bands.ini
From continuum_bands.ini
# this is everything
TALL 1.0m 1e-6m 10000.0m