Bowen O I spectrum does not include Lybeta pumping
We had reported the Bowen O I spectrum as a series of lines with the label 6lev. These were multiplets and included Lyb pumping. They are now reported as Blnds, but the Lyb pump is not included.
there was a discussion of this by email but, unfortunately, not on the google group.