Balmer limit double precision wavelength
The all-double run of the test suite produced the following errors:
limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_Fuji.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_Fuji.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_Fuji.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_Fuji.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_VR62.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_VR62.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_VR62.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_VR62.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_VS80.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_VS80.out: WARNING: no exact matching lines found for "Ca B" 3673.76A limit_caseb_h_den4_temp4_VS80.out: WARNING: no exact matching lines found for "H 1" 3673.76A limit_caseb_h_den4_temp4_VS80.out: WARNING: no exact matching lines found for "Ca B" 3673.76A
Cloudy recommends the following wavelength changes in each of the .out files:
WARNING: no exact matching lines found for "H 1" 3673.76A Taking best match as "H 1 3673.77A" WARNING: no exact matching lines found for "Ca B" 3673.76A Taking best match as "Ca B 3673.77A"
The exact wavelength, from NIST, is 3673.7649A. Normal runs round down to .76A, while double precision runs round up to .77A. The only way to reconcile the two would be to increase the line precision to 7, but that, currently, breaks all other lines in the test suite.
The relevant monitor command has been commented out in these files (2021/03/22).